The optimum width of an extractor hood



Promising kitchen ventilation systems!

An extractor can only unfold its full effect if it is in the right position. In addition, the performance and dimensions should be adapted to the hob, the room size and the cooking habits.


Hood width: plays a decisive role in determining the optimum extraction performance!
 

The further an updraft extractor hood is from the cooking surface, the wider it should be. This ensures that the vapour is properly extracted. If the hood is positioned higher up for tall cooks, a wide hood is better. The same applies to wide hobs. For 60 to 70 cm wide hobs, a hood width of 90 cm is optimal. If the hob is 100 cm wide, the hood should be 120 cm wide.

The right capacity for an extractor hood


It depends on the type of extractor, its position and the volume of the room. The air flow rate is measured in cubic metres of air per hour (m³/h). The European Ecodesign Directive 2009/125/EC limits the maximum air output at the highest normal setting to 650 m³/h. An intensive level can provide even more power, but it must turn off automatically after a certain amount of time.

Recirculation hoods require higher performance than exhaust hoods, as the odour filters reduce the flow rate. The same applies to very long, poorly planned or unfavourably laid exhaust ducts. The following table therefore specifies a performance supplement for such constellations. Naber components, such as the COMPAIR® air ducts, always extract the best performance from an extractor fan.

The table gives the recommended minimum and maximum capacity for a 2.5-metre-high kitchen as an example. For higher rooms, special ground plans and individual device combinations, the kitchen professional calculates the right performance level.


The room dimensions determine the air flow rate of the extractor hood
 

Area of the kitchen m2

Minimum capacity m3/h

Maximum capacity m3/h

3/h

10 150 300 400
20 200 450 600
30 250 600 650
40 300 650 650

*The supplement is recommended for recirculating air systems and not for optimal exhaust air ducting. Air change 1/h.
Source: extract from the worksheet AMK-MB-008 draft 04/2018 from the work group Die Moderne Küche e.V.